Automation · Windlass Systems · CAN Network Diagnostics
Quick PCS Dual-Windlass Control-Network Diagnostics
Vessel identity and client information withheld.

The Challenge
Remote/proportional control was unavailable while both windlasses remained functional through local foot controls.
Work Performed
Verified local operation, inspected interfaces and GTW/VFD connections, tested M12 cabling and conductor continuity, temporarily installed a compatible termination resistor, isolated network sections, and performed repeated power-cycle tests.
Result
Local windlass operation was confirmed and the recurring Error 12 was documented as a network-level fault requiring additional authorized diagnostics.
Authorized diagnostic scope completed. The affected system was isolated and documented; additional corrective work was deferred pending separate authorization.
Status
diagnostic
Authorized diagnostic scope completed.
Systems Involved
Quick PCS, PCS GTW interfaces, VFDs, M12 CAN network
Categories
Automation, Windlass Systems, CAN Network Diagnostics